This diagnostic procedure supports the following DTC:
DTC P0748 Pressure Control (PC) Solenoid Control Circuit
• | The transmission control module (TCM) detects that the feedback voltage is greater than 4.9 volts and detects the detection 500 milliseconds continuously. The pressure control solenoid (PCS) circuit is short to battery. |
• | The TCM detects that the feedback voltage is less than 70 mV for 70 milliseconds and detects the 12.5 seconds continuously. The PCS circuit is short to ground or open. |
• | The TCM will request the illumination of the hold lamp and store the DTC when the TCM detects a failure on the first ignition cycle. |
• | No lockup control |
• | No engine torque reduction control |
• | No engagement pressure control |
• | No 4th gear |
• | No self-learning control |
• | After failure decision: emergency mode |
• | The TCM turns off the hold lamp when no further failures are detected on the next ignition cycles. |
• | The scan tool can clear the DTC from the TCM history. |
• | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
• | The TCM detects the feedback voltage is between 70 mV and 4.9 volts for 12.5 seconds continuously. |
• | The wiring harness or connector between PCS and TCM |
• | The PCS |
• | The TCM |
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Automatic Transmission? | -- | Go to Step 2 | |
2 |
Is the hold lamp ON? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is DTC P0748 displayed? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the measurement within the specified values? | 20°C (68°F) 5.0-5.6 Ω | Go to Step 6 | Go to Step 7 |
5 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
6 |
Is the connection condition OK? | -- | Go to Step 8 | Go to Step 5 |
7 |
Is the measurement within the specified values? | 20°C (68°F) 5.0-5.6 Ω | Go to Step 9 | Go to Step 10 |
8 |
Is DTC displayed? | -- | Go to Step 2 | System OK |
9 |
Is the condition OK? | -- | Go to Step 2 | Go to Step 12 |
10 |
Is the condition found? | -- | Go to Step 13 | Go to Step 11 |
11 |
Is the condition OK? | -- | Go to Step 5 | Go to Step 12 |
12 | Replace the transaxle harness. Did you complete the replacement? | -- | System OK | -- |
13 | Replace the valve body assembly. Refer to Control Valve Body Disassemble . Did you complete the replacement? | -- | System OK | -- |
This diagnostic procedure supports the following DTC:
DTC P0748 Pressure Control (PC) Solenoid Control Circuit
• | The transmission control module (TCM) detects that the feedback voltage is greater than 4.9 volts and detects the detection 500 milliseconds continuously. The pressure control solenoid (PCS) circuit is short to battery. |
• | The TCM detects that the feedback voltage is less than 70 mV for 70 milliseconds and detects the 12.5 seconds continuously. The PCS circuit is short to ground or open. |
• | The TCM will request the illumination of the malfunction indicator lamp (MIL) and store the DTC when the TCM detects a failure on the first ignition cycle. |
• | No lockup control |
• | No engine torque reduction control |
• | No engagement pressure control |
• | No 4th gear |
• | No self-learning control |
• | After failure decision: emergency mode |
• | The TCM turns off the MIL when no further failures are detected on the next ignition cycle. |
• | The scan tool can clear the DTC from the TCM history. |
• | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
• | The TCM detects the feedback voltage is between 70 mV and 4.9 volts for 12.5 seconds continuously. |
• | The wiring harness or the connector between the PCS and the TCM |
• | The PCS |
• | The TCM |
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Automatic Transmission? | -- | Go to Step 2 | |
2 |
Is the malfunction indicator lamp (MIL) ON? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is DTC P0748 displayed? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the measurement within the specified values? | 20°C (68°F) 5.0-5.6 Ω | Go to Step 6 | Go to Step 7 |
5 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
6 |
Is the connection condition OK? | -- | Go to Step 8 | Go to Step 5 |
7 |
Is the measurement within the specified values? | 20°C (68°F) 5.0-5.6 Ω | Go to Step 9 | Go to Step 10 |
8 |
Is DTC displayed? | -- | Go to Step 2 | System OK |
9 |
Is the condition OK? | -- | Go to Step 2 | Go to Step 12 |
10 |
Is the condition found? | -- | Go to Step 13 | Go to Step 11 |
11 |
Is the condition OK? | -- | Go to Step 5 | Go to Step 12 |
12 | Replace the transaxle harness. Did you complete the replacement? | -- | System OK | -- |
13 | Replace the valve body assembly. Refer to Control Valve Body Disassemble . Did you complete the replacement? | -- | System OK | -- |