Catalytic Converter Replacement 1.4L LDT/1.6L LXV
Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Disconnect the front heated oxygen sensor connector.
- Remove the oil level gage tube.
- Remove the exhaust manifold heat shield.
- Remove the catalytic converter upper flange nuts.
- Remove the exhaust front pipe mounting bracket bolt.
- Remove the catalytic converter lower flange nuts.
- Remove the catalytic converter and the gasket.
Installation Procedure
- Install the catalytic converter and the gasket.
Caution: Refer to Fastener Caution in the Preface section.
Note: Position the catalytic converter onto the exhaust manifold flange with one upper flange nut.
- Install the catalytic converter lower flange nuts and the exhaust front pipe mounting bracket and tighten.
• | The exhaust front pipe to catalytic converter nuts to 40 N·m (30 lb ft). |
• | The exhaust front pipe mounting bracket bolt to 40 N·m (30 lb ft). |
- Install the catalytic converter upper flange nuts to exhaust manifold nuts to 40 N·m (30 lb ft).
- Install the exhaust manifold heat shield and tighten to
8 N·m (5.9 lb ft).
Note: Check the oil. If the oil dropped when removing the oil level gage tube, check and refill it.
- Install the oil level gage tube.
- Connect the front heated oxygen sensor connector.
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
Catalytic Converter Replacement 1.2L
Removal Procedure
Warning: Refer to Exhaust Service Warning in the Preface section.
Caution: Refer to Flex Decoupler Caution in the Preface section.
Caution: Refer to Catalytic Converter Movement Caution in the Preface section.
- Remove the exhaust manifold cover with the bolts.
- Remove the catalytic converter upper flange nut.
- Remove the connecting pipe mounting bracket bolt.
- Remove the catalytic converter lower flange nuts.
- Remove the catalytic converter and the gasket.
Installation Procedure
- Install the catalytic converter and the gasket.
Caution: Refer to Fastener Caution in the Preface section.
Note: Position the catalytic converter onto the exhaust manifold flange with one upper flange nut.
- Install the catalytic converter lower flange nuts and the connecting pipe mounting bracket and tighten.
• | The connecting pipe to catalytic converter nuts to 40 N·m (30 lb ft). |
• | The connecting pipe mounting bracket bolt to 40 N·m (30 lb ft). |
- Install the catalytic converter upper flange nuts and tighten to
50 N·m (37 lb ft).
- Install the exhaust manifold cover bolts and tighten to
15 N·m (11 lb ft).