Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Test fuse F14. Is fuse F14 open? | -- | Go to Step 2 | Go to Step 3 |
2 |
Is the repair complete? | -- | System OK | -- |
3 | Use a voltmeter to check for power to fuse F14. Does the battery voltage available at fuse F14 equal the value specified? | 11-14 V | Go to Step 5 | Go to Step 4 |
4 | Repair the power supply circuit to fuse F14. Is the repair complete? | -- | System OK | -- |
5 |
Does the battery voltage available at connector terminal 8 equal the value specified? | 11-14 V | Go to Step 6 | Go to Step 9 |
6 |
Does the ohmmeter indicate continuity? | -- | Go to Step 7 | Go to Step 9 |
7 |
Does the ohmmeter indicate continuity? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair the open circuit between the hazard switch connector terminal 8 and fuse F14. Is the repair complete? | -- | System OK | -- |
9 | Replace the faulty hazard switch. Refer to Hazard Warning Switch Replacement . Is the repair complete? | -- | System OK | -- |