• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition 1 Voltage | * | P0031, P0037 | -- | -- |
HO2S 1 Heater Control | P0031 | P0031, P0135 | P0032 | P0135 |
HO2S 2 Heater Control | P0037 | P0037, P0141 | P0038 | P0141 |
* Engine cranks but does not run and the fuse for the ignition circuit opens. |
The heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content in the exhaust stream. The HO2S must reach operating temperature to provide an accurate voltage signal. A heating element inside the HO2S minimizes the time required for the sensor to reach operating temperature. Voltage is provided to the heater by the ignition 1 voltage circuit through a fuse. Ground is provided to the heater on the low control circuit by a low side driver within the control module.
The HO2S utilizes the following circuits:
• | A signal circuit |
• | A low reference circuit |
• | An ignition 1 voltage circuit |
• | A heater control circuit |
• | The engine is running. |
• | The ignition 1 voltage is between 7.5-16 volts. |
• | The DTCs run continuously when the above conditions are met. |
The engine control module (ECM) detects an open, short to ground, or voltage on the control circuit of the HO2S.
• | DTC P0031, P0032, P0037, and P0038 are Type A DTCs. |
• | The ECM commands the fuel control system to open loop. |
DTC P0031, P0032, P0037, and P0038 are Type A DTCs.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: It may take up to 8 minutes for the DTC to set.
⇒ | If the test lamp does not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition 1 voltage circuit fuse is open, test all components connected to the ignition 1 voltage circuit and replace as necessary. |
• | HO2S (EURO IV) control circuit terminal 2 |
• | HO2S (Non EURO IV) control circuit terminal 3 |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
• | HO2S (EURO IV) control circuit terminal 2 |
• | HO2S (Non EURO IV) control circuit terminal 3 |
⇒ | If not within the specified range, replace the HO2S sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |