J 39400-A Halogen Leak Detector
Important: NEW CVC compressor assemblies are shipped with a partial poly-alkylene glycol (PAG) refrigerant oil charge. Use of the incorrect PAG oil can result in compressor failure.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 25 N·m (18 lb ft).
Tighten
Tighten the bolt to 20 N·m (15 lb ft).
Tighten
Tighten the pump bolt to 10 N·m (88 lb in).
• | J 39400-A Halogen Leak Detector |
• | J 44811 Accessory Belt Tensioner Unloader |
Important: NEW CVC compressor assemblies are shipped with a partial poly-alkylene glycol (PAG) refrigerant oil charge. Use of the incorrect PAG oil can result in compressor failure.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 25 N·m (18 lb ft).
Tighten
Tighten the bolt to 20 N·m (15 lb ft).
• | J 39400-A Halogen Leak Detector |
• | J 44811 Accessory Belt Tensioner Unloader |
Notice: Do NOT mix refrigerant oils. Use of incorrect refrigerant oil will cause compressor failure. This compressor uses a low viscosity refrigerant oil, Saturn P/N 22695048.
Important: NEW compressor assemblies are shipped with a partial poly-alkylene glycol (PAG) refrigerant oil charge. Use of the incorrect PAG oil can result in compressor failure.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 22 N·m (16 lb ft).
Tighten
Tighten the bolt to 20 N·m (15 lb ft).