The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply. Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the tensioner. Refer to Engine Mechanical for tensioner information.
Important: Service the generator as a complete unit.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
• | Tighten the bolts to 50 N·m (37 lb ft). |
• | Tighten the nuts to 30 N·m (22 lb ft). |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 22 N·m (16 lb ft).
Tighten
Tighten the nut to 20 N·m (15 lb ft).
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts/stud to 50 N·m (37 lb ft).
Tighten
Tighten the nut to 30 N·m (22 lb ft).