This test resets HVAC control module and checks for current air temperature actuator DTC.
This checks for proper operation of coolant system to ensure heater output.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted or the heating is insufficient. | ||||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||||
Does the scan tool display DTCs? | -- | Go to Step 3 | ||||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||
4 | Does the blower motor operate at the desired speeds? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | -- | Go to Step 6 | |||||||||||||
6 | Does the Too Cold in Vehicle concern occur when heating or defrosting is desired? | -- | Go to Step 7 | Go to Step 9 | ||||||||||||
7 |
Does the A/C compressor operate? | -- | Go to Step 8 | |||||||||||||
Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 9 | |||||||||||||
9 | Inspect the upper and lower air temperature sensors for the following conditions:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 10 | ||||||||||||
10 |
Does the paper stay in place? | -- | Go to Step 11 | Go to Step 14 | ||||||||||||
11 |
For the upper and lower duct temp parameter conversion from counts to temp, refer to Sensor Resistance Table . Does the scan tool indicate that the sensor temperatures are within the specification at the thermometer temperatures? | -3 to +3°C (-5 to +5°F) | Go to Step 12 | Go to Step 17 | ||||||||||||
12 |
Does the scan tool indicate that the sunload sensor parameter is greater than the specified value? | 224 Counts | Go to Step 13 | Go to Step 19 | ||||||||||||
13 |
Do the counts change? | -- | System OK | Go to Step 19 | ||||||||||||
14 | Test the ignition 3 voltage circuit of the HVAC control module for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 15 | ||||||||||||
15 | Test the battery positive voltage circuit of the HVAC control module for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 16 | ||||||||||||
16 | Test the ground circuit of the HVAC control module for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 20 | ||||||||||||
17 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table? | -- | Go to Step 20 | Go to Step 18 | ||||||||||||
18 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 21 | ||||||||||||
19 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 22 | ||||||||||||
20 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 23 | ||||||||||||
21 | Replace the appropriate temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
22 | Replace the ambient light sensor. Refer to Ambient Light Sensor Replacement . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
23 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |