Air Cleaner Element Replacement NT7
Removal Procedure
- Disconnect the mass air flow (MAF) sensor harness connector.
- Remove the upper air cleaner cover screws.
- Remove the upper air cleaner cover.
- Remove the air cleaner filter from the lower air cleaner housing.
- Inspect the air cleaner filter for dust, dirt and water contamination.
- Replace as necessary. Refer to
Maintenance Schedule.
Installation Procedure
- Install the air cleaner filter into the lower air cleaner housing.
- Install the upper air cleaner cover to the lower air cleaner housing.
Notice: Refer to Fastener Notice in the Preface section.
- Secure the air cleaner housing cover.
Tighten
Tighten the air cleaner cover screws to 5 N·m (44 lb in).
- Connect the MAF sensor harness connector.