• | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . |
• | Inspect the air delivery system for the following conditions: |
- | An obstruction to the airflow |
- | Air leaks |
- | Misaligned air ducts |
- | Broken or binding linkages or doors |
The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||
2 |
Does the scan tool indicate that the Recirculation and Outside Air Switch Parameters changes state? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||||
3 | Test the recirculation door control A circuit and the recirculation door control B circuit for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 4 | ||||||||
Does the actuator shaft rotate in both directions? | Go to Step 5 | Go to Step 6 | |||||||||
5 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 8 | ||||||||
6 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 7 | ||||||||
7 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 9 | -- | ||||||||
8 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 9 | -- | ||||||||
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |