Diagnostic Instructions
Circuit/System Description
When the ignition is turned ON, the instrument panel cluster (IPC) flashes the AIR BAG indicator 7 times for a bulb check. The inflatable restraint sensing and diagnostic module (SDM) performs diagnostic tests on the SIR system during the bulb check.
If any malfunction exists the SDM will request the IPC to illuminate the AIR BAG indicator steady, via serial data. If a preexisting malfunction exists, the AIR BAG indicator will illuminate steady immediately after the ignition is turned ON. If the ignition 1
voltage is outside of the normal operating voltage range 9-16 volts, the SDM will command the IPC to illuminate the AIR BAG indicator with no DTCs present, then disables all deployment loops.
Diagnostic Aids
• | If the ignition 1 voltage for the SDM is outside of the normal operating voltage range, 9-16 volts, the AIR BAG indicator will continuously illuminate and no DTC will set. |
• | The loss of serial data communication between the SDM and the IPC will cause the AIR BAG indicator to continuously illuminate. |
Reference Information
Schematic Reference
SIR Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
SIR System Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References
for scan tool information
Circuit/System Testing
- Ignition ON, with a scan tool, verify the Battery Voltage Signal Parameter is 9-16 volts.
- Ignition OFF, monitor the IPC, ignition ON. The SIR warning indicator should flash then turn OFF.
⇒ | If the SIR warning indicator continually flashes, program the SDM. |
- With a scan tool, perform the Display Test in Instrument Panel Cluster/Special Functions. The AIR BAG indicator should turn ON and OFF as commanded.
⇒ | If the AIR BAG indicator does not illuminate as expected, replace the IPC. |
- If all tests are normal, replace the SDM.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.