Removal Procedure


    Object Number: 1587822  Size: SH
  1. Remove the positive crankcase ventilation (PCV) fresh air tube from the air cleaner outlet duct.

  2. Object Number: 1587825  Size: SH
  3. Loosen the air cleaner outlet duct clamps at the mass air flow (MAF)/intake air temperature (IAT) sensor and throttle body.
  4. Remove the air cleaner outlet duct bolt (1).
  5. Remove the air cleaner outlet duct.

Installation Procedure

    Caution: Refer to Fastener Caution in the Preface section.


    Object Number: 1587825  Size: SH
  1. Install the air cleaner outlet duct.
  2. Install the air cleaner outlet duct bolt (1).
  3. Tighten
    Tighten the bolt to 10 N·m (89 lb in).

  4. Tighten the air cleaner outlet duct clamps at the MAF/IAT sensor and throttle body.
  5. Tighten
    Tighten the clamps to 2 N·m (18 lb in).


    Object Number: 1587822  Size: SH
  6. Install the PCV fresh air tube to the air cleaner intake duct.