Generator Bracket Replacement LZ4
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Rotate the drive belt tensioner counterclockwise.
- Remove the accessory drive belt. Refer to
Drive Belt Replacement.
- Remove the generator. Refer to
Generator Replacement.
- Remove the drive belt tensioner bolt.
- Remove the drive belt tensioner.
- Remove the drive belt idler pulley bolt.
- Remove the drive belt idler pulley.
- Remove the generator bracket bolts.
- Remove the generator bracket.
Installation Procedure
- Install the generator bracket.
Caution: Refer to Fastener Caution in the Preface section.
- Install the generator bracket bolts.
Tighten
Tighten the bolts in sequence to 50 N·m (37 lb ft).
- Install the drive belt tensioner.
- Install the drive belt tensioner bolt.
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the drive belt idler pulley.
- Install the drive belt idler pulley bolt.
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the generator. Refer to
Generator Replacement.
- Rotate the drive belt tensioner counterclockwise.
- Install the accessory drive belt. Refer to
Drive Belt Replacement.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.