• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition Voltage Supply - HO2S Bank 1 and 2 Sensor 1 | P0030, P0031, P0050, P0051 | P0050, P0051, P0134, P0135, P0154, P0155 | -- | -- |
Ignition Voltage Supply - HO2S Bank 1 and 2 Sensor 2 | P0036, P0037, P0056, P0057 | P0036, P0037, P0056, P0057, P0140, P0160 | -- | -- |
HO2S Bank 1 Sensor 1 Heater Control | P0031 | P0030, P0134 | P0032 | P0135 |
HO2S Bank 1 Sensor 2 Heater Control | P0037 | P0036, P0140 | P0038 | P0141 |
HO2S Bank 2 Sensor 1 Heater Control | P0051 | P0050, P0154 | P0052 | P0155 |
HO2S Bank 2 Sensor 2 Heater Control | P0057 | P0056, P0160 | P0058 | P0161 |
The heated oxygen sensor (HO2S) heater reduces the time required for the oxygen sensor to reach operating temperature and maintains the operating temperature during extended idle periods. When the ignition is turned to the ON position, ignition voltage is supplied directly to the sensor heater. The engine control module (ECM) controls the heater operation by first modulating the control circuit to ground when the sensors are cold. This prevents the possibility of thermal shock to the sensor, from condensation build-up on the sensor, by controlling the sensor's rate of heating. After a predetermined amount of time, the ECM commands the heaters ON continuously. Once the sensor reaches operating temperature, the ECM may modulate the heater control circuit to ground to maintain a desired temperature. The ECM controls the heater by grounding the control circuit with a solid state device called a driver. The driver is equipped with a feedback circuit that is pulled up to voltage. The ECM can determine if the control circuit is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.
• | Before the ECM can report DTC P0135 or P0155 failed, P0030, P0031, P0032, P0050, P0051, and P0052 must run and pass. |
• | DTC P0130, P0131, P0132, P0134, P0150, P0151, P0152, or P0154 is not set. |
• | The engine is operating. |
• | The ignition voltage is 10-18 volts. |
• | The intake air temperature (IAT) is warmer than -30°C (-22°F). |
• | After the previous ignition cycle the engine OFF time was greater than 0 seconds. |
• | The calculated exhaust temperature is colder than 524°C (975°F). |
• | The engine is not in decel fuel cut-off (DFCO). |
• | The HO2S 1 is at operating temperature for greater than 10 seconds. |
• | The internal HO2S 1 resistance is less than 10,000 ohms. |
• | DTCs P0135 and P0155 run continuously once the above conditions are met for approximately 100 seconds. |
• | Before the ECM can report DTC P0141 or P0161 failed, DTCs P0036, P0037, P0038, P0056, P0057, and P0058 must run and pass. |
• | DTCs P0137, P0138, P0140, P0157, P0158, or P0160 are not set. |
• | The engine is operating. |
• | The ignition voltage is 10-18 volts. |
• | The intake air temperature (IAT) is warmer than -30°C (-22°F). |
• | After the previous ignition cycle the engine OFF time was greater than 0 seconds. |
• | The calculated exhaust temperature is 300-550°C (572-1,022°F). |
• | The engine is not in decel fuel cut-off (DFCO). |
• | The internal HO2S 2 resistance is less than 10,000 ohms. |
• | The HO2S 2 heater is enabled for greater than 120 seconds. |
• | DTCs P0141 and P0161 run continuously once the above conditions are met for approximately 100 seconds. |
The ECM detects that the internal resistance of an HO2S 1 or HO2S 2 heater is not within the expected range.
DTCs P0135, P0141, P0155, and P0161 are Type B DTCs.
DTCs P0135, P0141, P0155, and P0161 are Type B DTCs.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Note: It may take up to 8 minutes for the DTC to set.
⇒ | If less than the specified value, repair the ignition voltage circuit of the HO2S heater for a short to ground or an open/high resistance. |
⇒ | If test lamp illuminates, test the heater control circuit for a short to ground. If the circuit/connections test normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for an open/high resistance. If the circuit/connections test normal, replace the ECM. |
Note: The control circuit for the HO2S heater is pulled-up to voltage within the ECM, 2.0-3.0 volts on the control circuit is normal.
⇒ | If not within the specified range, test the control circuit for a short to voltage. If the circuit/connections test normal, replace the ECM. |
⇒ | If the resistance is out of the specified range, replace the HO2S. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |