• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
CTSY/TRN SIG RT FRT Fuse B+ Terminal 2 X4 | B2615 00 | B2615 00 | -- | -- |
Courtesy Lamps Control | B2615 00 | B2615 00 | B2615 00 | -- |
The body control module (BCM) applies battery voltage to the courtesy lamps through the courtesy lamp control circuit. When any door is opened, the jam switch contacts close and the BCM receives a door-ajar input. If the BCM receives a door lock or unlock input or a rear hatch open input, the BCM will activate the courtesy lamp control circuit, providing battery voltage to all of the instrument panel (I/P) courtesy lamps, rearview mirror lamps, and rear compartment lamps. In the event that any of these lamps were to remain illuminated for more than 20 minutes with the ignition switch in the OFF position, the BCM will deactivate the inadvertent power courtesy lamp control circuit to prevent a total battery discharge condition.
Battery voltage must be between 9-16 volts.
DTC B2615 00 will set for the following conditions:
• | The BCM detects a short to voltage, short to ground, or an open/high resistance in the courtesy lamps control circuit. |
• | The BCM detects a short to ground or an open/high resistance in the CTSY/TRN SIG RT FRT fuse B+ circuit terminal 2 X4. |
The BCM will not illuminate any courtesy lamps supplied by the courtesy lamps control circuit.
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred. |
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
• | Dome/reading lamps - with CF5 |
• | Dome lamp - front - without CF5 |
• | Dome lamp - rear |
• | Ignition key cylinder lamp |
• | Dome/reading lamps terminal 4 - with CF5 |
• | Dome lamp - front terminal 4 - without CF5 |
• | Dome lamp - rear terminal 2 |
• | Ignition key cylinder lamp terminal A |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the DTC resets as current, test or replace the component responsible for setting the DTC. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |