The numbers below refer to the step numbers on the diagnostic table.
Lack of communication may be due to a partial or total malfunction of the class 2 serial data circuit or due to a partial or total malfunction of the UART data circuit. The specified procedure will determine the particular condition.
The symptom list in Symptoms will determine the correct diagnostic procedure to use.
The presence of DTCs which begin with "U" indicate some other module is not communicating. The specified procedure will collect all the available information before you perform tests.
Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | Perform the Battery Inspection/Test. Refer to Battery Inspection/Test . Does the battery pass the test? | Go to Step 2 | -- | ||||||||
2 |
Does the scan tool power up? | Go to Step 3 | Go to Scan Tool Does Not Power Up in Data Link Communications | ||||||||
Does the scan tool communicate with all of the modules? | Go to Step 4 | Go to Scan Tool Does Not Communicate with Class 2 Device in Data Link Communications | |||||||||
Does the scan tool display any DTCs? | Go to Step 5 | ||||||||||
Does the scan tool display any DTCs which begin with a "U"? | Go to Scan Tool Does Not Communicate with Class 2 Device in Data Link Communications | Go to Step 6 | |||||||||
6 | Does the scan tool display any DTCs which begin with a "B"? | Go to Diagnostic Trouble Code (DTC) List in Body Control System |