Removal Procedure
- Remove the air cleaner assembly intake duct. Refer to
Air Cleaner Assembly Replacement
.
- Remove the accessory drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
.
- Remove the generator. Refer to
Generator Replacement
.
- Remove the front generator bracket bolt and front bracket.
- Remove the generator rear mounting bolt to the engine (2).
- Remove the generator rear bracket.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator rear bracket and bolt (2) to the engine .
Tighten
Tighten the generator rear mounting bolt to the engine (2) to 50 N·m (37 lb ft).
- Install the generator front bracket and bolt to the engine.
Tighten
Tighten the generator bracket bolt to 50 N·m (37 lb ft).
- Install the generator. Refer to
Generator Replacement
.
- Install the accessory drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
.
- Install the air cleaner assembly intake duct. Refer to
Air Cleaner Assembly Replacement
.