Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Electrical Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 | Turn the ignition to the START position. Did the starter solenoid click? | Go to Step 3 | |
3 | Inspect the engine and belt drive system for mechanical binding (seized engine, seized generator). Does the engine move freely? | Go to Step 4 | Go to Engine Will Not Crank - Crankshaft Will Not Rotate in Engine Mechanical - 6.0L |
4 | Test the battery positive cable between the underhood fuse block and starter motor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 5 |
5 | Inspect for poor connections at the starter motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
6 | Replace the starter motor. Refer to Starter Motor Replacement . Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |