Removal Procedure
- Remove the instrument panel compartment door. Refer to
Instrument Panel Compartment Door Replacement
.
- Remove the 6 screws (1) attaching the instrument panel compartment
door trim (3) to the instrument panel compartment door (2).
- Lift up the upper edge of the trim panel (3) from the compartment
door (2) and unclip the retaining tabs securing the lower edges of the trim
panel (3) and the compartment door (2) together.
- Remove the trim panel (3) from the instrument compartment panel
door (2).
- Remove the 9 screws (5) securing the reinforcement (1)
to the instrument panel compartment door (3) and remove the reinforcement (1).
Important: The absorber (2) and the liner (4) are adhered to the reinforcement (1).
If either are removed a new item will have to be fitted as damage will occur during
the removal process.
- Remove the absorber (2) from the reinforcement (1)
- Remove any remaining absorber material from the reinforcement surface.
- Remove the liner (4) from the reinforcement (1).
- Remove any remaining liner material from the reinforcement surface.
- Unclip the instrument panel compartment latch rod (2)
from the instrument panel compartment latch handle (1) and the instrument panel
compartment latch assembly (4).
- Remove the three screws (5) attaching the latch assembly (4)
to the reinforcement.
- Remove the latch assembly (4) from the reinforcement.
Installation Procedure
- Install the latch assembly (4) to the reinforcement.
Notice: Refer to Fastener Notice in the Preface section.
- Install the 3 screws (5) attaching the latch assembly (4)
to the reinforcement.
Tighten
Tighten the 3 screws to 2 N·m (18 lb in).
- Install the instrument panel compartment latch rod (2) to the instrument
panel compartment latch handle (1) and the instrument panel compartment latch
assembly (4).
- Clean the surface of the reinforcement (1) to
remove all residual liner material and adhesive.
- Remove protective film from the new liner (4) and adhere the liner (4)
to the reinforcement (1).
- Clean the surface of the reinforcement (1) to remove all residual
absorber material and adhesive.
- Remove protective film from the new absorber (2) and adhere the
liner (2) to the reinforcement (1).
- Install the reinforcement (1) to the instrument panel compartment
door (3).
- Install the 9 screws (5) securing the reinforcement (1)
to the instrument panel compartment door (3).
Tighten
Tighten the 9 screws to 2 N·m (18 lb in).
- Install the trim panel (3) to the instrument panel
compartment door (2), making sure the retaining tabs that fasten the trim panel (3)
to the instrument panel compartment door (2) are engaged.
- Install the 6 screws (1) attaching the trim panel (3)
to the instrument panel compartment door (2).
Tighten
Tighten the 6 screws to 2 N·m (18 lb in).
- Install the instrument panel compartment door. Refer to
Instrument Panel Compartment Door Replacement
.