Removal Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
- Disable the SIR system. Refer to
SIR Disabling and Enabling
.
- Remove the instrument panel (I/P) trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel,
Gages and Console.
- Disconnect the I/P module connector (2).
- Remove the I/P module retaining nuts (3).
- Remove the I/P module retaining bolts (4).
- Remove the inflatable restraint I/P module (1).
- Fully deploy the module before disposal. If the module was replaced under
warranty, fully deploy and dispose of the module after the required retention period.
Refer to
Inflator Module Handling and Scrapping
.
Installation Procedure
- Install the inflatable restraint I/P module (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the I/P module retaining nuts (3).
Tighten
Tighten fasteners to 45 N·m (33 lb ft).
- Install the I/P module retaining bolts (4).
Tighten
Tighten fasteners to 9.5 N·m (84 lb in).
- Connect the I/P module connector (2).
- Install the I/P trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gages
and Console.
- Enable the SIR system. Refer to
SIR Disabling and Enabling
.