Air Inlet Valve Actuator Replacement for Pontiac GTO 2006
Removal Procedure
- Remove
the left side closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages, and Console.
- Remove the body control module (BCM). Refer to
Body Control Module Replacement
in Computer/Integrating Systems.
- Disconnect the vacuum line (12) from the actuator (11).
- Remove the clip (6), spacers (5) and actuator rod (7)
from the lever (4).
- Remove the actuator retaining screws (9).
- Remove the actuator from the HVAC unit (10).
Installation Procedure
- Install
the actuator (11) to the HVAC unit (10).
Notice: Refer to Fastener Notice in the Preface section.
- Secure the actuator with the retaining screws (9).
Tighten
Tighten the nuts to 4 N·m (35 lb in).
- Install the clip (6), spacers (5) and actuator rod (7)
to the lever (4).
- Connect the vacuum line (12) to the actuator.
- Install the BCM. Refer to
Body Control Module Replacement
in Computer/Integrating Systems.
- Install the left side closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages,
and Console.