Removal Procedure
- Relieve fuel system pressure.
Refer to
Fuel Pressure Relief
.
- Drain fuel tank. Refer to
Fuel Tank Draining
.
- Remove the fuel tank. Refer to
Fuel Tank Replacement
.
- Remove the fuel sender assembly. Refer to
Fuel Sender Assembly Replacement
.
- Remove the bumper from modular fuel sender assembly.
- Remove the fuel level sensor (1) from modular fuel sender.
Installation Procedure
- Fuel level sensor (1)
to modular fuel sender.
- Install the bumper to modular fuel sender assembly.
- Install the fuel sender assembly. Refer to
Fuel Sender Assembly Replacement
.
- Install the fuel tank. Refer to
Fuel Tank Replacement
.
- Refill tank.
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Reconnect
the negative battery cable.
- Check for fuel leaks.
7.1. | Turn the ignition switch ON for 2 seconds. |
7.2. | Turn the ignition switch OFF for 10 seconds. |
7.3. | Turn the ignition switch ON. |
7.4. | Check for fuel leaks. |