- Connect the inflatable
restraint IP module connector (3) located above the RH IP wiring harness
junction block.
- Install the connector position assurance (CPA) (2) to the
IP module connector (3).
- Install the RH IP wiring harness junction block access panel.
- Connect the inflatable
restraint steering wheel module coil connector (1) located above the
LH IP wiring harness junction block.
- Install the CPA (2) to the steering wheel module coil connector (1).
- Install the AIR BAG Fuse to the LH IP wiring harness junction
block.
- Install the LH IP wiring harness junction block access panel.
- Staying well away from both air bags, turn ON the ignition.
8.1. | The AIR BAG indicator will flash seven times. |
8.2. | The AIR BAG indicator will then turn OFF. |
- Perform
Diagnostic System Check - SIR
if the AIR BAG indicator does not operate as described.