Removal Procedure
- Disconnect the evaporative emission (EVAP) canister purge valve
harness connector.
- Disconnect the vacuum pipe from the EVAP canister purge valve.
- Disconnect the purge pipe from the EVAP canister purge valve.
- Remove the EVAP canister
purge valve and bracket.
- Remove the EVAP canister purge valve from the purge bracket.
- Inspect for carbon release in the EVAP canister purge valve ports.
Refer to
Evaporative Emission System Cleaning
.
Installation Procedure
- Install the EVAP canister purge valve on to the purge bracket.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the EVAP
canister purge valve and bracket.
Tighten
Tighten the purge bracket nut to 8 N·m (71 lb in).
- Connect the purge pipe to the EVAP canister purge valve.
- Connect the vacuum pipe to the EVAP canister purge valve.
- Connect the EVAP canister purge valve harness connector.