• | J 25025 Guide Pins |
• | J 36850 Assembly Lubricant |
• | Bent or stuck thermal elements |
• | Plugged holes |
• | Damage from being bent |
• | Plugged or damaged solenoid screens |
Important: Be sure that the check ball valves do not fall out of the valve body assembly during installation.
Important: Tighten and torque the bolts in a spiral pattern starting from the center. If the bolts are torqued at random, valve bores may become distorted and inhibit proper valve operation.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
• | Tighten bolts 380, 379, 375 to 25 N·m (18 lb ft). |
• | Tighten bolts 376, 378 to 12 N·m (106 lb in). |
• | Tighten bolts 377 to 12 N·m (106 lb in). |