Compressor Control Valve Assembly Removal V5- Conventional Mount
Tools Required
• | J 39500-B R-134a
Air Conditioning Refrigerant Recovery, Recycling And Recharging System |
- Recover the refrigerant using the J 39500-B
.
- Remove the control valve retaining ring using the J 5403
.
- Remove the control valve assembly (5).
Compressor Control Valve Assembly Removal V5- Direct Mount
Tool Required
J 41790-A Compressor
Holding Fixture
- Install the compressor onto the J 41790-A
.
- Remove the compressor control valve retaining ring using internal
snap ring pliers.
- Remove the compressor control valve from the compressor.