Compressor Control Valve Assembly Install V5- Conventional Mount
Tools Required
J 5403 Snap Ring
Pliers
- Coat the O-rings with
525 viscosity refrigeration oil.
- Using thumb pressure, push the O-rings in place.
Important: Ensure that the retaining ring is properly seated in the ring groove.
- Using the J 5403
,
install the valve retaining ring with the high point of the curved sides
against the valve housing.
- Evacuate the system. Recharge the system.
- Perform a leak test. Refer to Compressor Leak Testing (V5- Conventional Mount)
.
Compressor Control Valve Assembly Install V5- Direct Mount
- Coat the control valve O-rings with clean 525 viscosity refrigeration
oil.
- Push the compressor control valve into the compressor with thumb
pressure.
- Using internal snap ring pliers, install the compressor control
valve retaining ring.
Make sure the retaining ring is properly seated in the ring groove.
- Remove the compressor from the J 41790-A
.