The ignition switch supplies Ignition 1 voltage to the inflatable restraint Sensing and Diagnostic Module (SDM) at terminal 10 using the SIR Fuse. The ignition switch also supplies Ignition 1 voltage to the AIR BAG warning lamp using the IP-IGN Fuse. The AIR BAG warning lamp is connected to the INFLATABLE RESTRAINT INDICATOR at terminal 7 of the SDM. When the ignition switch is first turned to the RUN position, the SDM responds by flashing the AIR BAG warning lamp seven times.

When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.

Test Description

The numbers below refer to the step numbers on the diagnostic table:

  1. This test determines whether the malfunction is in the inflatable restraint Sensing and Diagnostic Module (SDM) circuitry or in the instrument cluster power feed circuitry.

  2. This test determines whether voltage is present in the warning lamp circuit.

  3. This test isolates CKT 358 and checks for a short in CKT 358 to B+.

  4. This test determines if the malfunction is in the instrument cluster connector.

  5. This test determines if the open is due to a bad bulb.

  6. This test isolates an open in the warning lamp circuitry.

  7. This test checks whether power is available to the instrument cluster power feed circuit.

  8. This test checks for a short from the instrument cluster power feed circuit to ground.

  9. This test determines whether the short to ground is due to a short in the wiring or internal to the instrument cluster.

  10. This test determines if the malfunction is in the instrument cluster connector.

  11. This test determines whether the malfunction is due to an open power feed circuit from the IPC Fuse.

Air Bag Warning Lamp Does Not Come On

Step

Action

Value(s)

Yes

No

1

Was the SIR Diagnostic System Check performed?

--

Go to Step 2

Go to SIR Diagnostic System Check

2

  1. Set the parking brake.
  2. Turn the ignition switch to the RUN position.

Does the BRAKE indicator light?

--

Go to Step 3

Go to Step 13

3

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the inflatable restraint steering wheel and IP module yellow 2-way connectors located near the base of the steering column.
  3. Disconnect the inflatable restraint Sensing and Diagnostic Module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement .
  4. Install J 38715-96 SIR Shorting Bar Tool to the SDM harness connector.
  5. Install the CPA.
  6. Turn the ignition switch to the RUN position.
  7. Measure the voltage on the SDM harness connector from terminal 7 to ground.

Is the voltage more than the specified value?

10.0 V

Go to Step 4

Go to Step 6

4

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.
  3. Turn the ignition switch to the RUN position.
  4. Measure the voltage on the SDM harness connector from terminal 7 to ground.

Is the voltage less than the specified value?

1.0 V

Go to Sensing and Diagnostic Module Integrity Check

Go to Step 5

5

  1. Turn the ignition switch to the OFF position.
  2. Repair a short-to-B+ condition in CKT 358.
  3. Reconnect the instrument cluster.

Are the repairs complete?

--

Go to Step 24

--

6

  1. Turn the ignition switch to the OFF position.
  2. Remove the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.
  3. Check for proper connection to the instrument cluster at terminal H C2.

Is the connector damaged or corroded?

--

Go to Step 7

Go to Step 8

7

Repair the instrument cluster harness connector. Refer to Connector Repairs in Electrical Diagnosis.

Are the repairs complete?

--

Go to Step 24

--

8

  1. Remove the AIR BAG warning lamp bulb. Refer to Instrument Cluster Lamps in Instrument Panel, Gauges and Console.
  2. Inspect the bulb.

Is the bulb good?

--

Go to Step 10

Go to Step 9

9

  1. Replace the AIR BAG warning lamp bulb. Refer to AIR BAG Indicator Replacement .
  2. Install the instrument cluster.

Are the repairs complete?

--

Go to Step 24

--

10

  1. Install the AIR BAG warning lamp bulb.
  2. Measure the resistance from the instrument cluster harness connector terminal H C2 to the SDM harness connector terminal 7.

Is the resistance within the specified values?

0-5 ohms

Go to Step 12

Go to Step 11

11

  1. Repair an open condition in CKT 358.
  2. Install the instrument cluster.

Are the repairs complete?

--

Go to Step 24

--

12

Service the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.

Are the repairs complete?

--

Go to Step 24

--

13

  1. Turn the ignition switch to the OFF position.
  2. Remove the IP-IGN Fuse.
  3. Inspect the fuse.

Is the fuse good?

--

Go to Step 19

Go to Step 14

14

  1. Replace the fuse.
  2. Turn the ignition switch to the RUN position for 10 seconds.
  3. Turn the ignition switch to the OFF position.
  4. Remove the IP-IGN Fuse.
  5. Inspect the fuse.

Is the fuse good?

--

Go to Step 18

Go to Step 15

15

  1. Disconnect the inflatable restraint steering wheel and IP module yellow 2-way connectors at the base of the steering wheel.
  2. Disconnect the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.
  3. Replace the IP-IGN Fuse.
  4. Turn the ignition switch to the RUN position for 10 seconds.
  5. Turn the ignition switch to the OFF position.
  6. Remove the IP-IGN Fuse.
  7. Inspect the fuse.

Is the fuse good?

--

Go to Step 17

Go to Step 16

16

  1. Repair a short-to-ground condition in CKT 39.
  2. Replace the IP-IGN Fuse.

Are the repairs complete?

--

Go to Step 24

--

17

  1. Service the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.
  2. Install the IP-IGN Fuse.

Are the repairs complete?

--

Go to Step 24

--

18

Install the IP-IGN Fuse.

Are the repairs complete?

--

Go to Step 24

--

19

  1. Remove the instrument cluster. Refer to Instrument Panel Cluster in Instrument Panel, Gauges and Console.
  2. Check for proper connection to the instrument cluster at terminal I C2.

Is the connector damaged or corroded?

--

Go to Step 20

Go to Step 21

20

Repair the instrument cluster harness connector. Refer to Connector Repairs in Electrical Diagnosis.

Are the repairs complete?

--

Go to Step 24

--

21

Measure the resistance between the instrument cluster harness connector terminal I C2 to each terminal of the IP-IGN Fuse fuseholder.

Is either reading within the specified values?

0-5 ohms

Go to Step 23

Go to Step 22

22

  1. Repair an open condition in CKT 39.
  2. Install the IP-IGN Fuse.

Are the repairs complete?

--

Go to Step 24

--

23

  1. Repair an open condition in the power feed to the IP-IGN Fuse.
  2. Install the IP-IGN Fuse.

Are the repairs complete?

--

Go to Step 24

--

24

Reconnect all the SIR system components, make sure all the components are properly mounted.

Have all the SIR components been reconnected and properly mounted?

--