Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the measured voltage within the specified range? | 4-6 V | Go to Step 2 | Go to Step 3 |
2 | Use a DMM in order to measure the voltage between the sun load temperature sensor harness connector terminal A (circuit 590) and terminal B (circuit 61). Is the measured voltage within the specified range? | 4-6 V | Go to Step 4 | Go to Step 5 |
3 | Locate and repair a poor connection or an open in circuit 590 (LT BLU/BLK) between the sun load temperature sensor harness connector terminal A and the heater-A/C control harness connector terminal C2. Is the repair complete? | -- | Go to Step 6 | -- |
4 | Replace the sun load temperature sensor. Refer to Sun Load Sensor Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
5 | Locate and repair a poor connection or an open in circuit 61 (YEL) between the sun load temperature sensor harness connector terminal B and splice S 258. Is the repair complete? | -- | Go to Step 6 | -- |
6 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
7 | Verify that the systems operate properly. Does the system operate properly? | -- | System OK | Go to Diagnostic System Check |