Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement
.
- Use a small flat-bladed tool in order
to remove the wiring harness from the solenoid valves (315A, 315B, 322,
334 and/or 440), TFP manual valve position switch (395) and/or the temperature
sensor (391).
- Remove the wiring harness (224).
Installation Procedure
- Install the wiring harness (224).
- Connect the wiring harness to the solenoid
valves (315A, 315B, 322, 334 and/or 440), TFP manual valve
position switch (395) and/or the temperature sensor (391).
- Install the case side cover. Refer to
Control Valve Body Cover Replacement
.