• | EVAP purge solenoid |
• | Throttle position (T/P) sensor |
• | Idle air control (IAC) valve |
• | Manifold absolute pressure (MAP) sensor |
• | Mass air flow (MAF) sensor |
• | Throttle body |
• | Manifold absolute pressure (MAP) sensor |
• | Positive crankcase ventilation (PCV) valve |
• | Vacuum source manifold |
• | Vacuum source manifold |
• | Positive crankcase ventilation (PCV) valve |
• | Manifold absolute pressure (MAP) sensor |
• | Throttle body |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the bolts in sequence to 10 N·m (89 lb in).
• | Mass air flow (MAF) sensor |
• | Manifold absolute pressure (MAP) sensor |
• | Idle air control (IAC) valve |
• | Throttle position (T/P) sensor |
• | EVAP purge solenoid |
Tighten
Tighten the bolt to 16 N·m (12 lb in).
Tighten
Tighten the nut and the bolt to 10 N·m (89 lb in).