Generator Noise
Important: Automotive generators produce a certain amount of low level sound during
normal operation. This sound is caused by a combination of mechanical and
electrical/magnetic conditions in the generator. Typically, the sound level
will be higher during periods of high output demand on the generator. Objectionable
noise from a generator may be caused by conditions causing normal sound
to be transmitted directly to the passenger compartment, by mounting problems,
or by internal generator conditions. The following can cause objectionable
noise:
• | Improper routing of hoses, wiring, shielding, etc., against the
generator |
• | Faulty or damaged diode, stator, or rotor |
If the generator is suspected of causing excessive noise, compare the
noise level to another vehicle that is equipped with the same generator in
order to determine if the noise level is normal.
Generator Output/Load Test
Tools Required
J 39200 Digital Multimeter
(DMM)
Important: If a charging system tester is used, ensure that the inductive lead
is installed properly in order to obtain an accurate amperage reading.
If an automated charging system tester is used, follow the manufacturers
instructions for proper connection and operation of the tester.
If an automated charging system tester is not available, perform the
following steps:
- Install the ammeter lead to the generator B+ lead. If an in-line
ammeter is used, perform the following steps:
1.2. | Remove the generator B+ lead from the generator B+ terminal. |
| Important: Insulate the ammeter connections in order to prevent a short.
|
1.3. | Install the ammeter between the generator output B+ terminal and the
engine wiring harness. |
- Turn the carbon pile (load tester) off.
- Connect the carbon pile (load tester) across the battery terminals.
- Start the engine.
- Raise the engine speed to 2000 RPM.
- Turn the carbon pile (load tester) on.
- Adjust the load to the proper level according to the generator
(RPO code).
• | If the vehicle is equipped with the Bosch KCB2 generator (K68),
adjust the carbon pile load to 73 amperes. |
• | If the vehicle is equipped with the Bosch NCB1 generator (KG9),
adjust the carbon pile load to 85 amperes. |
- | If the load test amperage value cannot be obtained and the voltage
reading falls below 13.0, replace the generator. Refer to
Generator Replacement
. |
- | If the load test amperage value cannot be obtained and the voltage
reading is between the minimum and the maximum, a carbon pile (load tester)
failure is the cause of the problem. |
- With the carbon pile load still applied, use the J 39200
to inspect the battery voltage. If
the voltage is below 13.0 or above 15.5, replace the generator.
Refer to
Generator Replacement
.