Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the keyless entry diagnostic system check? | -- | Go to Step 2 | |
2 |
Do all of the doors lock and unlock when using both door lock switch? | -- | Go to Step 3 | |
3 |
Did the test lamp illuminate? | -- | Go to Step 4 | Go to Step 5 |
4 | Test for a poor connector terminal contact at the RCDLR. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 8 |
5 | Using a test lamp, connect between the RCDLR harness connector terminal C and ground. Did the test lamp illuminate? | -- | Go to Step 6 | Go to Step 7 |
6 | Repair a poor connection or an open in circuit 1550. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
7 | Repair a poor connection or an open in circuit 640. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
8 |
Did the keyless entry system operate normally? | -- | System OK | Go to Step 9 |
9 |
Important: Perform the RCDLR programming procedure when replacing the RCDLR. Refer to Transmitter Programming . Replace the RCDLR. Refer to Receiver Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |