Condition
| Cause
| Action
|
The power sliding door does not power unlatch/open when
the open/close switch is pressed. The door may power open if the door
is manually unlatched.
| The following conditions may prevent the unlatch actuator from activating:
• | Circuit 750 and/or circuit 2910 is open. |
• | The unlatch actuator is defective. |
The following conditions may prevent the unlatch actuator and rod from
unlatching or opening the door:
• | The sliding door is locked. |
• | The front rod adjustment is too long. |
• | The unlatch actuator is defective. |
|
- Perform the Diagnostic Mode 3. Refer to Diagnostic Modes in
Power Sliding Door (PSD) Diagnostic Information
. Perform the indicated corrective action.
- Complete one of the following actions:
|
The following conditions exist:
• | The PSD unlatches but does not power open when you press the open/close
switch. |
• | The PSD does not power open if you move the door manually. |
| There is
an electrical malfunction within the PSD system.
| Refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
One of the following conditions exists:
• | The PSD unlatches but does not power open when you press the open/close
switch. The PSD power opens if you move the door manually. |
• | The PSD does not power open when you activate the handle. The
PSD power opens when you move the door manually. |
|
• | There is a malfunction in the detent switch circuit. |
• | The door lock rod is out of adjustment. |
• | An electric noise is present. |
|
• | Repair the electric noise: |
- | Verify that the pads and plungers are securely attached to the
body and the door. Replace the pouch fastener, as needed. |
- | Inspect for corrosion, water entry, and dirty or sticking plungers.
Clean or replace the plungers as needed. |
- | Inspect the ground circuits. |
- | Inspect the detent switch. Replace the detent switch as needed.
Refer to Rear Latch Detent Switch - Power Sliding Door. |
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
The PSD reverses or
stops during a power opening.
|
• | There is a mechanical obstruction. |
• | The cable tension is incorrect. |
|
- Complete the following steps in order to clear the mechanical
obstruction as needed:
• | Remove any foreign objects. Clean or replace the track, as needed. |
• | Inspect the roller brackets for binding. Adjust the lower track.
Use lithium grease in order to lubricate the lower track at the bend. |
• | Inspect the roller brackets for wear. Replace the brackets as
needed. |
- Adjust the cable tension. Refer to Cable Tension Adjustment -
Sliding Door (Regular Method) for regular method or Cable Tension Adjustment
- Sliding Door (Alternate Method) for atlernate method in Doors.
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
The sliding door does
not remain open when the vehicle is on a hill (incline or decline).
|
• | The cable tension is incorrect. |
• | The hold open system is faulty. |
|
• | Adjust the cable tension. Refer to Cable Tension Adjustment -
Sliding Door (Regular Method) for regular method or Cable Tension Adjustment
- Sliding Door (Alternate Method) for atlernate method in Doors. |
• | Adjust, clean, or replace the hold open spring/retainer. |
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|