The number(s) below refer to the step number(s) on the diagnostic table.
The specified values are from the A/C System Performance Test.
This checks for proper air temperature actuator movement.
The voltage will vary between 0.25-14.7 volts during normal operation. The HVAC control module connector must be connected during this step. This checks for proper operation of the air temperature actuator door control circuit and the HVAC control module.
The voltage will vary between 0.25-14.7 volts during normal operation. The HVAC control module connector must be connected during this step. This checks for proper operation of the air temperature actuator door control circuit and the HVAC control.
The auxiliary blower motor switch control circuit should not have continuity to ground when front auxiliary blower control switch is in any position except REAR CNTL.
The voltage will vary between 0.25-14.7 volts during normal operation. The auxiliary HVAC control module connector must be connected during this step. This checks for proper operation of the air temperature actuator door control circuit and the auxiliary HVAC control module.
This step checks complete auxiliary air temperature door control circuit from the HVAC control module to the auxiliary HVAC control module to the auxiliary air temperature actuator.
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Auxiliary air temperature can not be adjusted from one or both auxiliary controls or auxiliary heating is insufficient. | ||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||
2 |
Does the auxiliary blower motor operate at all? | -- | Go to Step 3 | |||||||||||
3 | Does the auxiliary blower motor operate in each speed position? | -- | Go to Step 4 | |||||||||||
4 |
Does the A/C compressor operate? | -- | Go to Step 5 | |||||||||||
Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 6 | |||||||||||
6 | Does the Auxiliary Too Cold in Vehicle condition happen with front HVAC control and auxiliary HVAC control modules? | -- | Go to Step 9 | Go to Step 7 | ||||||||||
7 | Does the Auxiliary Too Cold in Vehicle condition happen with front HVAC control module? | -- | Go to Step 13 | Go to Step 8 | ||||||||||
8 | Does the Auxiliary Too Cold in Vehicle condition happen with auxiliary HVAC control module? | -- | Go to Step 16 | Go to Too Cold in Vehicle | ||||||||||
Does the air temperature actuator move with a smooth transition between COLD and HOT? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 10 | |||||||||||
Does the voltage measure within the specified values with a smooth transition between COLD and HOT? | 0.25-14.7 V | Go to Step 11 | Go to Step 20 | |||||||||||
11 | Connect a test lamp between the ignition 3 voltage circuit and the ground circuit of the auxiliary air temperature actuator. Does the test lamp illuminate? | -- | Go to Step 19 | Go to Step 12 | ||||||||||
12 | Connect a test lamp between the ignition 3 voltage circuit and a good ground. Does the test lamp illuminate? | -- | Go to Step 21 | Go to Step 22 | ||||||||||
Does the voltage measure within the specified values with a smooth transition between COLD and HOT? | 0.25-14.7 V | Go to Step 14 | Go to Step 23 | |||||||||||
Does the test lamp illuminate? | -- | Go to Step 24 | Go to Step 15 | |||||||||||
15 | Connect a test lamp between the ignition 3 voltage circuit and a good ground . Does the test lamp illuminate? | -- | Go to Step 30 | Go to Step 25 | ||||||||||
Does the voltage measure within the specified values with a smooth transition between COLD and HOT? | 0.25-14.7 V | Go to Step 17 | Go to Step 26 | |||||||||||
17 |
Does the test lamp illuminate? | -- | Go to Step 25 | Go to Step 18 | ||||||||||
18 | Connect test lamp between the ignition 3 voltage circuit of the auxiliary HVAC control module and a good ground. Does the test lamp illuminate? | -- | Go to Step 27 | Go to Step 28 | ||||||||||
19 | Inspect the auxiliary air temperature door and the auxiliary air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 29 | ||||||||||
Test the auxiliary air temperature door control circuit of the auxiliary air temperature actuator from the front HVAC control module to the auxiliary air temperature actuator for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 25 | |||||||||||
21 | Test the ground circuit of the auxiliary air temperature actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 29 | ||||||||||
22 | Test the ignition 3 voltage circuit of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 29 | ||||||||||
23 | Test the auxiliary air temperature door control circuit of the auxiliary air temperature actuator from the HVAC control module to the auxiliary HVAC control module for an open, high resistance, short to ground, and short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 30 | ||||||||||
24 | Test the rear auxiliary blower motor control circuit for short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 30 | ||||||||||
25 | Test the ignition 3 voltage circuit of the auxiliary HVAC control module for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 32 | ||||||||||
26 | Test the auxiliary air temperature position signal circuit of the auxiliary air temperature actuator from the auxiliary HVAC control module to the HVAC control module for an open, high resistance, short to ground, and short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 31 | ||||||||||
27 | Test the rear auxiliary blower motor control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 31 | ||||||||||
28 | Test the ignition 3 voltage circuit of the auxiliary HVAC control module for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 31 | ||||||||||
29 | Inspect for poor connections at the harness connector of the auxiliary air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 32 | ||||||||||
30 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 33 | ||||||||||
31 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 35 | Go to Step 34 | ||||||||||
32 | Replace the auxiliary air temperature actuator. Refer to Auxiliary Temperature Valve Actuator Replacement . Did you complete the replacement? | -- | Go to Step 35 | -- | ||||||||||
33 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 35 | -- | ||||||||||
34 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | -- | Go to Step 35 | -- | ||||||||||
35 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |