The instrument panel cluster (IPC) contains a momentary switch that controls the trip odometer reset and trip season display options. The IPC monitors the circuit voltage levels and detects when the trip odometer reset switch has been depressed.
The IPC must have normal operating battery voltage.
The IPC detects that the trip reset switch input is low (grounded) for greater than 60 seconds.
The IPC will disable (ignore) the trip reset switch.
• | A current DTC B2823 will clear after a complete ignition cycle. |
• | A scan tool may be used to clear the DTC. |
• | The IPC will store the code as current only as long as the failure exists. An intermittent failure will be stored as a history DTC B2823. |
• | If DTC B2823 is set only in history, press and release the trip reset switch several times in order to verify the customer concern. |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics | |||
1 | Did you perform the IPC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool display Inactive? | Go to Step 3 | Go to Step 4 |
3 |
Does the Trip Reset Switch parameter change state and the odometer change from season to trip? | Go to Diagnostic Aids | Go to Step 4 |
4 |
Important:: Perform the set up procedure for the replacement IPC. Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | Go to Step 5 | -- |
5 |
Does the DTC reset? | Go to Step 2 | System OK |