Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Sliding Door Schematics Connector End View Reference: Power Door Systems Connector End Views | |||
1 | Did you perform the Power Door System Diagnostic System Check? | Go to Step 2 | |
2 |
Does the power sliding door remain closed and the alarm sound a tone when the OPEN/CLOSE switch is pressed? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the power sliding door open? | Go to Step 4 | Go to Step 5 |
4 | Test the park signal circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 | Replace the transaxle range switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transaxle. Is the repair complete? | Go to Step 7 | -- |
6 | Replace the rear side door actuator control module. Refer to Rear Side Door Actuator Control Module Replacement . Is the repair complete? | Go to Step 7 | -- |
7 | Re-initialize the power sliding door and operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |