Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is inoperative in all speed positions. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Does the auxiliary blower motor operate in any of the speed positions? | Go to Step 3 | ||
3 |
Does the test lamp illuminate? | -- | Go to Step 10 | Go to Step 4 |
4 | Test the battery positive voltage circuit of the auxiliary blower motor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 5 |
5 | Test the blower motor speed control circuit of the auxiliary blower motor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 6 |
6 |
Important: Ensure that the auxiliary blower motor resistor connector and the HVAC control module connectors are connected during this step in order to avoid misdiagnosis.
Does the voltage measure near the specified value? | 4-8 V | Go to Step 11 | Go to Step 7 |
7 |
Does the voltage measure near the specified value? | 4-6 V | Go to Step 9 | Go to Step 8 |
8 | Test the auxiliary blower motor speed control circuit of the HVAC control module for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 11 |
9 | Test the auxiliary blower motor speed control circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
10 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 13 |
11 | Inspect for poor connections at the harness connector of the auxiliary blower motor resistor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 14 |
12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 15 |
13 | Replace the auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
14 | Replace the auxiliary blower motor resistor. Refer to Auxiliary Blower Motor Resistor Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
15 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |