Special Tools
J-39400-A Halogen Leak Detector
Removal Procedure
- Disconnect the air conditioning (A/C) refrigerant pressure sensor electrical connector (1).
- Remove the A/C refrigerant pressure sensor (2).
- Inspect and replace the O-ring seal (3) as necessary.
Installation Procedure
Note: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the O-ring seal to enter the refrigerant system.
- Lightly coat the O-ring seal (3) with mineral base 525 viscosity oil.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C refrigerant pressure sensor (2) and tighten to
5 N·m (44 lb in)
.
- Connect the A/C refrigerant pressure sensor electrical connector (1).
- Leak test the fitting using the
J-39400-A detector
.