Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems. | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Are the fog lamps illuminated? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 | Remove the fog lamp relay. Are the fog lamps illuminated? | Go to Step 7 | Go to Step 4 |
4 | Using a test lamp connected to ground, probe the control circuit of the fog lamp relay connector. Does the test lamp illuminate? | Go to Step 5 | Go to Step 10 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 9 |
6 | Test the fog lamp relay control circuit for a short to battery positive voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 8 |
7 | Test the fog lamp supply voltage circuit for a short to battery positive voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 8 |
8 | Replace the fuse block - underhood. Refer to Underhood Electrical Center or Junction Block Replacement in Wiring Systems. Is the repair complete? | Go to Step 11 | -- |
9 | Replace the fog lamp switch. Refer to Instrument Panel Multifunction Switch Assembly Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | Go to Step 11 | -- |
10 | Replace the fog lamp relay. Refer to Relay Replacement in Wiring Systems. Is the repair complete? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |