The inflatable restraint I/P module deployment loop consists of a dual stage I/P module, I/P module high control, and I/P module low control circuits for both stages 1 and 2. There are 2 shorting bars used within the I/P module connector which will short together the I/P module high and I/P module low control circuits for both stages 1 and 2 when the connector is disconnected. This will help to prevent unwanted deployment of the inflator module during servicing. When the ignition is turned ON, the inflatable restraint sensing and diagnostic module (SDM) performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a diagnostic trouble code (DTC) will be stored in memory.
Ignition 1 voltage is within the normal operating voltage range.
• | DTC B0012--stage 2 or DTC B0016-stage 1 will set when the SDM detects the I/P module deployment loop resistance is less than 1.3 ohms for 500 milliseconds. |
• | DTC B0013--stage 2 or DTC B0017-stage 1 will set when one of the following conditions occurs: |
- | The SDM detects the I/P module deployment loop resistance is greater than 4.8 ohms for 500 milliseconds. |
- | The SDM detects the voltage at I/P module high control is less than 2.4 volts and I/P module deployment loop resistance is 6 ohms or greater for 500 milliseconds. |
• | DTC B0014-stage 2 or B0018-stage 1 will set when one of the following conditions occurs: |
- | The SDM detects the voltage at I/P module high control is shorted to ground or voltage for 500 milliseconds. |
- | The SDM detects the voltage at I/P module high control is less than 2.4 volts and I/P module deployment loop resistance is less than 6 ohms for 500 milliseconds. |
The SDM commands the AIR BAG indicator ON via Class 2 serial data.
• | The condition responsible for setting the DTC no longer exists. |
• | You issue a scan tool CLEAR DTCs command. |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred. |
The following can cause an intermittent condition:
• | A short between the I/P module stage 1 or stage 2, high and low control circuits |
• | An open or a high resistance in the I/P module stage 1 or stage 2, high or low control circuits |
• | A malfunctioning shorting bar on the I/P module connector |
Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Inspects the I/P module in-line connector.
Tests for a malfunctioning I/P module.
Tests for current DTCs. If DTC B0012 or B0016 is present, test for a short between the I/P module high and I/P module low control circuits for stage 1 or stage 2. If DTC B0013 or B0017 is present, test for an open or high resistance in the I/P module high and I/P module low control circuits for stage 1 or stage 2. If DTC B0014 or B0018 is present, test for a short to ground or voltage in the I/P module high and I/P module low control circuits for stage 1 or stage 2.
Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: SIR Schematics Connector End View Reference: SIR Connector End Views | |||||||||
1 | Did you perform the Diagnostic System Check - SIR? | Go to Step 2 | |||||||
Do the connectors exhibit any signs of corrosion, terminal damage, or poor connections? | Go to Step 3 | Go to Step 4 | |||||||
3 |
Did you complete the replacement? | Go to Step 9 | -- | ||||||
Important: When installing the J 38715-A SIR Driver/Passenger Load Tool for testing the dual stage I/P module, the correct 4-way load tool adapter must be used. Failure to use the correct 4-way load tool adapter will set additional codes when testing. Does the scan tool indicate that either DTC B0012, B0013, B0014, B0016, B0017, or B0018 is current? | Go to Step 5 | Go to Step 8 | |||||||
5 |
Did you find and correct the condition? | Go to Step 9 | Go to Step 6 | ||||||
Did you find and correct the condition? | Go to Step 9 | Go to Step 7 | |||||||
7 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | Go to Step 9 | -- | ||||||
8 | Replace the I/P module. Refer to Inflatable Restraint Instrument Panel Module Replacement . Did you complete the replacement? | Go to Step 9 | -- | ||||||
9 |
Does the DTC reset? | Go to Step 2 | System OK |