GM Service Manual Online
For 1990-2009 cars only

Object Number: 1584015  Size: MF

Callout

Component Name

Preliminary Procedure

  1. Remove the fuse labeled HVAC CTRL (BATT).
  2. Remove the air inlet assembly. Refer to Air Inlet Assembly Replacement .
  3. Disconnect the recirculation actuator electrical connector.

1

Recirculation Housing Screw (Qty: 6)

Notice: Refer to Fastener Notice in the Preface section.

Tighten
1.5 N·m (14 lb in)

2

Recirculation Housing

3

Recirculation Actuator Screw (Qty: 3)

Tighten
1.5 N·m (13 lb in)

4

Recirculation Actuator

Procedure

Recalibrate the Actuator. Refer to Actuator Recalibration