• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Hazard Switch Signal | 1 | 1 | -- | -- |
Instrument Panel Lamps Supply Voltage | B2625 02 | 2 | 2 | -- |
Hazard Switch Ground | -- | 1 | 1 | -- |
1. Hazard Lamps Malfunction 2. Interior Backlighting Malfunction |
The hazard flashers may be activated in any power mode. The hazard switch is permanently grounded through G300. When the hazard switch is placed in the ON position, ground is applied through the hazard switch signal circuit to the body control module (BCM). The BCM supplies battery voltage to all 4 turn signal lamps in an ON and OFF duty cycle. When the hazard switch is placed in the ON position, the instrument panel cluster (IPC) receives a signal from the BCM via GMLAN requesting both turn signal indicators to be cycled ON and OFF.
Lighting Systems Connector End Views
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal C for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Hazard Switch Signal | 1 | 1 | -- | -- |
Instrument Panel Lamps Supply Voltage | B2625 02 | 2 | 2 | -- |
Hazard Switch Ground | -- | 1 | 1 | -- |
1. Hazard Lamps Malfunction 2. Interior Backlighting Malfunction |
The hazard flashers may be activated in any power mode. The hazard switch is permanently grounded through G305. When the hazard switch is placed in the ON position, ground is applied through the hazard switch signal circuit to the body control module (BCM). The BCM supplies battery voltage to all 4 turn signal lamps in an ON and OFF duty cycle. When the hazard switch is placed in the ON position, the instrument panel cluster (IPC) receives a signal from the BCM via GMLAN requesting both turn signal indicators to be cycled ON and OFF.
Lighting Systems Connector End Views
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal D for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |