• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Battery Voltage - Relay Switch Side | ¹ | ² | -- | -- |
Fuel Pump Supply Voltage | ¹ | ² | ³ | -- |
Fuel Pump Relay Control | P0230 | P0230 | P0230 | -- |
Fuel Pump Relay Ground | -- | P0230 | P0230 | -- |
Fuel Pump Ground | -- | ² | -- | -- |
¹Open fuel pump fuse, cranks no start ²Cranks no start ³Fuel pump operates continuously, discharges battery |
The control module enables the fuel pump relay when the ignition switch is turned ON. The control module will disable the fuel pump relay within 2 seconds unless the control module detects ignition reference pulses. The control module continues to enable the fuel pump relay as long as ignition reference pulses are detected. The control module disables the fuel pump relay within 2 seconds if ignition reference pulses cease to be detected and the ignition remains ON.
The control module monitors the voltage on the fuel pump relay control circuit. If the control module detects an incorrect voltage on the fuel pump relay control circuit, a fuel pump relay control DTC sets.
• | The engine is cranking or running. |
• | The ignition voltage is between 11-18 volts. |
• | DTC P0230 runs continuously when the above conditions are met. |
• | The control module detects that the commanded state of the driver and the actual state of the control circuit do not match. |
• | The above condition is met for a minimum of 2.5 seconds. |
DTC P0230 is a Type B DTC.
DTC P0230 is a Type B DTC.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
J 43244 Relay Puller Pliers
Ignition ON, command the fuel pump relay ON and OFF with a scan tool. Listen/feel for relay to click and for fuel pump to turn ON and OFF.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |