Tools Required
J 22912-01 Split
Plate
Caution: When handling parts that have been preheated for installation purposes,
always wear leather welding gloves with a minimum amount of handling time.
Failure to wear leather gloves may result in severe skin burns or personal
injury.
Important: Heat the input shaft, collar and the stopper plate in an approved preheat
oven to approximately 95°C (200°F) just prior to removal. DO NOT use
an acetylene torch or other open flame. Always allow the preheated parts
to cool after removal. DO NOT quench the preheated parts with water. Use
compressed air to help cool any preheated parts.
- Remove the following items
as an assembly using the J 22912-01
(inverted) and a press:
• | The 4th gear bearing collar |
• | The 4th gear blocking ring |
• | The 3rd/4th synchronizer assembly |
• | The 3rd gear blocking ring |
- Remove the collar and
the stopper plate. Use a J 22912-01
(inverted) with a press. Discard the collar and the stopper plate.