Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the fog lamps remain illuminated? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 | Disconnect the fog lamp relay. Did the fog lamps turn off? | Go to Step 4 | Go to Step 6 |
4 | Test the fog lamp relay control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
5 | Inspect for poor connections at the fog lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
6 | Repair a short to voltage in the front fog lamp supply voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
7 | Replace the fog lamp relay. Refer to Fog Lamp Relay Replacement . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |