Removal Procedure
- Disconnect the air cleaner duct from the air cleaner resonator.
- Loosen the air cleaner outlet resonator to throttle body clamp (3),
accessed through the accelerator bracket (2) slot.
- Disconnect the intake air temperature (IAT) sensor
harness connector (4).
- Disconnect the vacuum pipe from the air cleaner resonator.
- Loosen the vent hose clamp
and move it away from the air cleaner resonator (2).
- Disconnect the vent hose (1) from the air cleaner resonator (2).
- Remove the air cleaner resonator (2) from the throttle body (3).
Installation Procedure
- Install the air cleaner
resonator to the throttle body.
- Connect the vent hose to the air cleaner resonator.
- Move the spring clamp over the air cleaner resonator vent port
and vent hose.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Tighten the resonator
to throttle body clamp.
Tighten
Tighten the clamp to 5 N·m (44 lb in).
- Connect the IAT sensor harness connector.
- Connect the vacuum pipe to the air cleaner resonator.
- Connect the air cleaner intake duct to the air cleaner resonator.
Tighten
Tighten the air cleaner intake duct clamp to 5 N·m (44 lb in).