Tools Required
Installation Procedure
Caution: Gasoline or gasoline vapors are highly flammable. A fire could occur
if an ignition source is present. Never drain or store gasoline or diesel
fuel in an open container, due to the possibility of fire or explosion. Have
a dry chemical (Class B) fire extinguisher nearby.
Notice: Clean all of the following areas before performing any disconnections
in order to avoid possible contamination in the system:
• | The fuel pipe connections |
• | The areas surrounding the connections |
- Relieve the fuel system
pressure. Refer to
Fuel Pressure Relief
.
- Disconnect the fuel feed hose (2) from the fuel rail (5).
Refer to
Metal Collar Quick Connect Fitting Service
.
- Install the J 29658-D
with the J 29658-500
between the fuel feed hose and fuel rail.
- Turn ON the ignition, with the engine OFF.
Caution: Do not drain the fuel into an open container. Never store the fuel in
an open container due to the possibility of a fire or an explosion.
- Place the
bleed hose of the fuel pressure gage into an approved gasoline container.
- Open the bleed valve on the fuel pressure gage in order to bleed
the air from the fuel pressure gage.
- Command the fuel pump ON with a scan tool.
- Close the bleed valve on the fuel pressure gage.
- Command the fuel pump ON with a scan tool.
- Inspect for fuel leaks.
Removal Procedure
- Relieve the fuel system
pressure. Refer to
Fuel Pressure Relief
.
- Remove the J 29658-D
with the J 29658-500
from the fuel feed hose and fuel rail.
- Connect the fuel feed (2) hose to the fuel rail (5). Refer to
Metal Collar Quick Connect Fitting Service
.
- Connect the negative battery cable.
- Turn ON the ignition, with the engine OFF.
- Inspect for fuel leaks.