The body control module (BCM) controls the unlocking function of the passenger door locks in parallel with the door lock switches. The ground is applied to the door lock actuator lock control circuit through the door lock portion of the door lock/unlock relay. When the BCM applies power to the door unlock control circuit, the door unlock portion of the door lock/unlock relay switches battery positive voltage to the door lock actuator unlock control circuit, energizing all of the passenger door lock actuators to unlock.
The BCM must be commanding all of the passenger door lock actuators to unlock.
• | The BCM detects an open or a short to ground in the door unlock relay control circuit while commanding all of the passenger door lock actuators to unlock. |
• | The condition above must be present for more than 0.3 seconds. |
The BCM stores DTC B3132 or B3133 in memory.
• | An open or a short to ground in the door unlock relay control circuit is no longer detected by the BCM. |
• | A history DTC B3132 or B3133 will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | If the DTC B3132 or B3133 is a history DTC, the fault may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
• | The following conditions may cause an intermittent malfunction to occur: |
- | An intermittent open or short to ground in the door unlock relay control circuit |
- | The BCM is intermittently open or shorted to ground internally |
The numbers below refer to the step numbers on the diagnostic table.
Listen for an audible noise when the door lock actuators are commanded to unlock. Command the door lock actuators to lock and unlock. Repeat the commands as necessary.
Verifies that the Body Control Module is providing voltage to the door unlock relay control circuit.
Tests for an open in the door lock/unlock relay ground circuit.
Tests if voltage is constantly being applied to the door unlock relay control circuit.
Tests for a stuck switch.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Door Lock/Indicator Schematics Connector End View Reference: Power Door Systems Connector End Views | |||
1 | Did you perform the Diagnostic System Check for the door systems? | Go to Step 2 | |
Do the door lock actuators lock and then unlock with each command? | Go to Diagnostic Aids | Go to Step 3 | |
Does the test lamp flash when the door locks are commanded to unlock? | Go to Step 4 | Go to Step 5 | |
Does the test lamp flash with each command? | Go to Step 9 | Go to Step 12 | |
Does the test lamp remain illuminated with each command? | Go to Step 6 | Go to Step 7 | |
While observing the test lamp, disconnect each door lock switch. Does the test lamp remain illuminated? | Go to Step 8 | Go to Step 10 | |
7 | Test the door unlock relay control circuit to the door lock/unlock relay for a short to ground or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 11 |
8 | Test the door unlock relay control circuit to the door lock/unlock relay for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the door lock/unlock relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
10 | Inspect for poor connections at the harness connector of the appropriate door lock switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
11 | Inspect for poor connections at the harness connector of the Body Control Module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
12 | Repair the ground circuit to the door lock/unlock relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
13 | Replace the door lock/unlock relay. Did you complete the repair? | Go to Step 16 | -- |
14 | Replace the appropriate door lock switch. Did you complete the repair? | Go to Step 16 | -- |
15 |
Did you complete the replacement? | Go to Step 16 | -- |
16 |
Does the DTC reset? | Go to Step 2 | System OK |