Removal Procedure
- Remove the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.
- Disconnect the recirculation actuator electrical connector.
- Remove the recirculation actuator retaining screws.
- Remove the recirculation actuator.
Installation Procedure
- Install the recirculation actuator to the HVAC module.
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator retaining screws.
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the recirculation actuator electrical connector.
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.