Removal Procedure
- Disconnect the electrical connector from the refrigerant pressure sensor.
- Remove the refrigerant pressure sensor from the compressor hose.
Installation Procedure
Important: Use R-12 refrigerant oil (mineral) to lubricate O-rings. Use of R-134a polyalkylene glycol (PAG) oil will cause premature corrosion of fitting joints.
- Lubricate the refrigerant pressure sensor O-ring with mineral oil. Refer to
O-Ring Replacement
.
Notice: Refer to Fastener Notice in the Preface section.
- Hand start the refrigerant pressure sensor to the compressor hose, taking care not to pinch the O-ring and tighten.
Tighten
Tighten the pressure sensor to 4 N·m (35 lb in).
- Install the electrical connector to the refrigerant pressure sensor.